Ciria Report 108 Concrete Pressure On Formwork ✰ [ FRESH ]
Research (including later CIRIA updates) shows that for SCC, the coefficient (1.2) is insufficient. SCC can maintain fluid-like behavior for longer, leading to near-hydrostatic pressures.
| Feature | CIRIA 108 (UK/Global) | ACI 347 (US) | | :--- | :--- | :--- | | | Setting time (E) and Rate (R) | Column size and pour rate | | Pressure Equation | P = 1.2 x D x R x E | P = D x (C1√R + C2) | | Minimum Value | 25 kN/m² | 30 kPa (624 psf) | | Best For | Walls, deep sections, controlled rates | Columns, moderate pours |
In the late 1970s and early 1980s, CIRIA undertook a massive research project, observing real-world pours in walls, columns, and slipforms. The result, published in , provided empirical evidence that concrete stiffens (develops "shear strength") as it hydrates, thereby reducing peak pressure significantly below the hydrostatic maximum. ciria report 108 concrete pressure on formwork
ACI 347 uses empirical curves based on column size. CIRIA 108 is more scientific for walls and unusual geometries because it explicitly accounts for the concrete's hydration chemistry. For complex projects, many engineers run both and use the higher (safer) value. Special Cases: Self-Compacting Concrete (SCC) Standard CIRIA 108 was written before SCC became ubiquitous. SCC has much higher flowability and longer setting retention. Does CIRIA 108 still apply?
Introduction In the world of concrete construction, few elements are as critical—and as often misunderstood—as lateral pressure on vertical formwork. Over-pour a wall or misjudge the setting rate of a column, and the result is a blowout: thousands of dollars in wasted material, potential worker injury, and crippled project timelines. Research (including later CIRIA updates) shows that for
For decades, engineers and contractors have relied on a single, authoritative document to navigate this risk:
Rearrange the formula: R_max = P_allowed / (1.2 × D × E) If your formwork is rated for 80 kN/m², you solve for R to determine the maximum trucks per hour. The result, published in , provided empirical evidence
Published by the Construction Industry Research and Information Association (CIRIA), Report 108 fundamentally changed how the industry calculates the lateral pressure exerted by fresh concrete. Even with the advent of Self-Compacting Concrete (SCC) and modern admixtures, the principles laid out in this 1985 report remain the industry benchmark.