Press and hold Up + Down simultaneously for 8 seconds until P01 appears.

Use Up/Down to select PXX, press Clock, adjust value with Up/Down, press Clock to save. Exit by holding Auto/Manual for 3 seconds. 8. Wiring Diagram and Terminal Assignments Danger: 230V AC present. Only for qualified installers. eberle instat 6 user manual english

| Parameter | Description | Range | Default | Typical setting | |-----------|-------------|-------|---------|------------------| | P01 | Temperature control type | 0=ON/OFF, 1=PID | 0 | 1 for underfloor heating, 0 for radiators | | P02 | Cycle time (minutes) – only for ON/OFF | 1-30 | 10 | 5 for gas boiler, 15 for electric | | P03 | Minimum setpoint limit | 5-15°C | 5 | 10 (to prevent excessive cooling) | | P04 | Maximum setpoint limit | 20-35°C | 30 | 27 | | P05 | Frost protection temperature | 5-15°C | 7 | 7 | | P06 | Open window detection sensitivity | 0=off, 1-3 (1=low) | 2 | 1 if room has frequent drafts | | P07 | Display brightness | 1-5 | 3 | 2 | | P08 | Sensor calibration offset | -3 to +3°C | 0 | Use if measured temp differs | Press and hold Up + Down simultaneously for